MIL-DTL-23053/16B
TABLE II. Physical properties. 1/ - Continued
Characteristic
Requirement
Test procedure and conditions
Fluid resistance,
4.6.11 2/
properties after:
Tensile strength,
1,500(10.4)
psi (MPa), minimum
Ultimate elongation,
200
percent, minimum
Dielectric strength,
200(7.9)
volts/mil (Kv/mm),
minimum
Flammability
Self-extin-
4.6.14 Procedure B
ASTM 2671
guishing within
one minute and
no more than 25
percent of
indicator flag
burned or
charred
Fungus resistance
Rating less
4.6.2 ASTM G21
than 1
1/ Unless otherwise specified, requirements, test procedures and conditions
are for all classes.
2/ In addition to the fluids specified in 4.6.11, the sleeving shall also be
immersed in diesel fuel conforming to MIL-F-46162.
Storage life conditions: Supplier shall certify to storage at 18° to 35°C (65°
to 95°F) for 2 years. Conformance to 3.5. See 3.5.2 for storage life extension.
Intended use: Heat shrinkable flexible elastomeric sleeving is intended for use
on heavy duty cables or harness systems, such as ground support which see high
levels of physical abuse and exposure to fuels and oils, coupled with high and
low temperature extremes.
4