MIL-DTL-23053/1C
Construction details, inches (mm). 1/ - Continued
TABLE I.
Military
As supplied
After unrestricted Shrinkage
Part Number 3/
ID minimum
Wall thickness 2/
ID maximum
M23053/1-207-0
1.000
(25.4)
.570
(14.5)
.070
±
.020
(1.77
±
.51)
M23053/1-208-0
1.250
(31.8)
.714
(18.1)
.087
±
.020
(2.20
±
.51)
M23053/1-209-0
1.500
(38.1)
.095
±
.020
(2.41
±
.51)
.857
(21.8)
.107
±
.020
(2.71
±
.51)
M23053/1-210-0
1.750
(44.5)
1.000
(25.4)
M23053/1-211-0
2.000
(50.8)
.110
±
.020
(2.79
±
.51)
1.140
(29.0)
M23053/1-212-0
3.000
(76.2)
.125
±
.020
(3.17
±
.51)
1.710
(43.4)
M23053/1-213-0
4.000
(101.6)
.140
±
.020
(3.55
±
.51)
2.280
(57.9)
1/ Diameter limits for the object to be enclosed shall be as recommended
in technical data.
2/ Wall thickness values are less when shrinkage is restricted.
3/ The color code identified is the standard acquisition color.
Unrestricted shrinkage procedures:
Test method 4.6.5; 175° ± 2°C (347° ± 4°F) for
10 minutes, maximum.
TABLE II.
Physical properties. 1/
Characteristic
Test procedure and condition
Requirement
As supplied:
ID, minimum
Table I
4.6.3.1.1
Low temperature
4.6.7.1 Class 1:-55° ± 2°C
No cracks
(-67° ± 4°F); Class 2:
flexibility
-70° ± 2°C (-94° ± 4°F)
Heat shock
No cracks,
4.6.8 Class 1: 150° ± 2°C;
flowing or
(302° ± 4°F); Class 2:
dripping
200° ± 2°C (392° ± 4°F)
Restricted shrinkage
No cracks
4.6.6.1.1 135° ± 2°C
(275° ± 4°F)
Voltage withstand
Pass
4.6.6.2
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business