MIL-DTL-23053/1C
TABLE II. Physical properties. 1/ - Continued
Characteristic
Requirement
Test procedure and
condition
Dielectric strength,
300 (11.8)
4.6.11
volt/roil (Kv/mm),
minimum
Fluid resistance,
Class 1 - 900 (6.2)
properties after:
Class 2 - 1,000 (6.9)
Tensile strength,
Class 1 - 150
psi (MPa), minimum
Class 2 - 175
Ultimate elongation,
Class 1 - 200 (7.9)
percent, minimum
Class 2 - 250 (9.8)
Dielectric strength,
4.6.14, Procedure A,
volts/roil (Kv/mm),
Self extinguishing
ASTM D2671
minimum
15 seconds; 3 inches
4.6.2 ASTM G21
Flammability
No growth
Fungus resistance
1/ Unless otherwise specified, requirements, test procedures and conditions
are for all classes.
Storage life conditions:
Supplier shall certify to storage at 18 to 35°C (65 to
95°F) for 1 year. Conformance to 3.5. for storage life extension.
Intended use: Heat shrinkable flexible polychloroprene sleeving is intended
for use on cables or harness systems in equipment that is subject to high
levels of physical abuse.
Custodians:
Preparing activity:
Army - ER