MIL-DTL-23053/15B
TABLE II. Physical properties. - Continued
Characteristic
Requirement
Test procedure and conditions
After unrestricted
shrinkage:
ID, maximum
Table I
4.6.3
Wall thickness
Table I
4.6.3
Tensile strength,
1200(8.3)
4.6.13 ASTM D638, 2
psi (MPa), minimum
inches/minute
Ultimate elongation,
200
4.6.13 ASTM D638, 2
percent, minimum
inches/minute
Dielectric strength,
200(7.9)
4.6.2 ASTM D2671
volts/roil (Kv/mm),
minimum
1013
Volume resistivity,
4.6.2 ASTM D876
Ohm-cm, minimum
Corrosion
4.6.10.1 and 4.6.10.2
No corrosion
121° ± 2°C (250° ± 4°F)
for 16 hours
Flammability
4.6.14 Procedure C
ASTM D2671
Water absorption,
4.6.2 ASTM D570 24 hrs
percent, maximum
at 23°C
Heat resistance,
4.6.9 175° ± 2°C
properties after:
(347° ± 4°F), 168 hours
Ultimate elongation,
100
percent, minimum
Tensile strength,
1,000(6.9)
psi (MPa), minimum
Fluid resistance,
4.6.11
properties after:
Tensile strength,
750 (5.2)
psi (MPa), minimum
4