MIL-DTL-23053/15B
TABLE II. Physical properties. - Continued
Characteristic
Requirement
Test procedure and conditions
Dielectric strength
200(7.9)
volts/roil (Kv/mm),
minimum
Fungus resistance
No growth
4.6.2 ASTM G21
1/
Record whether any flaming or glowing particles or flaming drops fall from
the specimen.
If more than 25 percent of the indicator flag is burned
away or charred (brown scorching and soot shall be ignored) after all of
the five applications of flame or if flaming or glowing particles or
flaming drops fall from the specimen at any time and ignite the cotton
(flameless charring of the cotton shall be ignored), the specimen shall be
judged to have conveyed flame and shall be considered as failing. In
addition, any specimen which continues to flame or glow from one flame
application longer than one minute shall not be acceptable.
Storage life conditions: Supplier shall certify to storage at 18° to 35°C (65°
to 95°F) for 2 years. Conformance to 3.5. See 3.5.2 for storage life extension.
Flammability:
Only the outer jacket is flame retardant.
Intended use: Heat shrinkable, flexible, heavy wall, coated sleeving is used
for repair of heavy duty cables, splice covers.
Custodians:
Preparing activity:
Army - ER
Navy - AS
Navy - AS
Air Force - 85
(Project 5970-1129-15)
5
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business