MIL-I-46865B (MI)
3.2.3 Viscosity. The viscosity of the thawed materials, as received, shall be as follows (see 4.7.4.3):
Type I 300 ± 100 centipoises (cP) Type II 850 ± 200 cP
Type III 7500 ± 2000 cP
3.2.4 Storage life. The premix, as furnished by the manufacturer, shall be capable of meeting the requirements specified herein after storage at a temperature of less than 40°C in an original closed container for not less than 3 months (see 4.7.4.4).
3.3 Performance characteristics.
3.3.1 Porosity. The cured compound shall exhibit no bubbles or porosity smaller than 0.031 inch diameter (see 4.7.4.5).
3.3.2 Hardness. The cured compound shall have a hardness value of not less than 40 Shore D as specified by ASTM D 2240 (see 4.7.4.6).
3.3.3 Flexibility. Bending shall cause no chipping or cracking (see 4.7.4.7).
3.3.4 Insulation resistance. The insulation resistance shall be not less than 1 x
1011 ohms (see 4.7.4.8).
3.4 Workmanship. The compound shall be uniform in quality and shall be free of dark colored contaminants, lumps, foreign materials, and other defects that could adversely affect its use.
4. QUALITY ASSURANCE PROVISIONS
4.1 Responsibility for inspection. Unless otherwise specified in the contract or purchase order, the contractor is responsible for the performance of all inspection requirements (examinations and tests) as specified herein. Except as otherwise specified in the contract or purchase order, the contractor may use his own or any other facilities suitable for the performance of the inspection requirements specified herein, unless disapproved by the Government. The Government reserves the right to perform any of the inspections set forth in this specification where such inspections are deemed necessary to ensure supplies and services conform to prescribed requirements.
4.1.1 Responsibility for compliance. All items shall meet all requirements of sections 3 and 5. The inspection set forth in this specification shall become a part of the contractor's overall inspections system or quality program. The absence of any inspection requirements in the specification shall not relieve the contractor of the